Flake ice machine (rotating evaporator) for connection to an external refrigeration unit or multicompressor refrigeration system
Ice output 6000 kg / 24 h
This machine type is part of the new HY-GEN flake ice line. The HY-GEN products have been designed in a completely new way and even the smallest screw is drafted to allow the production of flake ice that meets with strictest hygiene requirements. The core piece is the innovative evaporation tank in plastics, which can be easily removed for manual cleaning. Moreover, the evaporation tank is free from integral built-in parts, which make systematic cleaning complicate and difficult. Regarding water supply, MAJA trusts in innovative DVGW-compliant systems.
With the HY-GEN-philosophy, MAJA does not leave hygiene to chance any longer!
Equipment & features
Control panel standard
Standard control unit for MAJA Flake Ice Machines HY-GEN line.With START and STOP buttons for ice production. AUTO-CLEAN button for start of automatic evaportator self-cleaning system (only if option MAJA-SCS is installed). WATER button for drain water outlet. TEST button for automatic control if all machine parts are ready for operation after manual cleaning.
MAJA ref. | 010-0138 |
Output | 6000 kg / 24 h (13228 lbs) |
Water consumption | 6,0 m³ /24h |
Refrigeration capacity required | to - 22,0°C (-7,6°F) / 33,0 kW |
Width | 1860 mm (73.2 “) |
Depth | 1450 mm (57.0 “) |
Height | 586 mm (23.0 “) |
Refrigerant | R 404A, others on demand. |
Electrical connection 3AC/50Hz/400V/PE | 0,52 kW |
Special voltage | on demand |
Water connection | |
Weight | 320 kg (705 lbs) |
Notes | Water supply temperature: + 16°C (+60,8°F) Ambient temperature: + 20°C (+68,0°F) Higher temperatures may lead to reduced ice output. Water supply: ¾'' external thread; drain water 1'' hose clip. For optimized working conditions concerning ice capacity and ice quality a suction line heat exchanger is necessary |