Flake ice machine (rotating evaporator) for connection to an external refrigeration unit or multicompressor refrigeration system
The RVH 9000 consists of two separately operated rotating evaporator units for increased operation safety and individual control of ice output according to varying needs.
Ice output 9000 kg / 24 h
This machine type is part of the new HY-GEN flake ice line. The HY-GEN products have been designed in a completely new way and even the smallest screw is drafted to allow the production of flake ice that meets with strictest hygiene requirements. The core piece is the innovative evaporation tank in plastics, which can be easily removed for manual cleaning. Moreover, the evaporation tank is free from integral built-in parts, which make systematic cleaning complicate and difficult. Regarding water supply, MAJA trusts in innovative DVGW-compliant systems.
With the HY-GEN-philosophy, MAJA does not leave hygiene to chance any longer!
- HY-GEn protected - our label for hygiene in flake ice production!
- Flake ice for mincer process
- Rotating evaporator RVH connected to external condensing unit
- Rotating evaporator RVH integrated in multicompressor refrigeration system
Equipment & features
2 x Control panel standard
AUTO-CLEAN button for start of automatic evaportator self-cleaning system (only if option MAJA-SCS is installed).
WATER button for drain water outlet.
TEST button for automatic control if all machine parts are ready for operation after manual cleaning.
MAJA ref. | 010-0139 |
Output | 9000 kg / 24 h (19800 lbs / 24 h) |
Water consumption | 9,0 m³ /24h |
Refrigeration capacity required | to -22,0°C / 33,0 kW to -21,0°C / 16,2 kW |
Width | 1863 mm (73.4 “) |
Depth | 1456 mm (57.0 “) |
Height | 1572 mm (62.0 “) |
Refrigerant | R404A, others on demand |
Electrical connection 3AC/50Hz/400V/PE | 0,52 kW + 0,34 kW |
Water connection | |
Weight | 600 kg (1320 lbs) |
Notes | Water supply temperature: + 16°C (+60,8°F) Ambient temperature: + 20°C (+68,0°F) Higher temperatures may lead to reduced ice output. Water supply: ¾'' external thread; drain water 1'' hose clip. For optimized working conditions concerning ice capacity and ice quality a suction line heat exchanger is necessary. |